Recovery guide

How to put each instrument back on its official firmware, and what to back up first. Plain steps, no jokes.

Last updated October 14, 2026

Before you start

  1. Back up everything the instrument holds. Presets, samples, patterns, projects. The steps for each instrument are below.
  2. Keep your own copy of the official firmware for the version you’re running. We never host or link firmware, so we can’t give you one later.
  3. Use a computer, a good USB cable plugged straight into it (no hub), and the instrument’s own power supply. A firmware update that loses power halfway is the most common way to get into trouble.
  4. Read the whole section for your instrument once before you begin.

Don't update your instrument's firmware to a newer version until the compatibility table lists it as ✅ works or 🧪 in beta. A new official version can arrive before we've made the mod work on it. Keep your own copy of the official firmware file you're running now. Already updated? The recovery guide shows how to go back.

MicroFreak

Rehearsed. We walked these steps end to end on our own MicroFreak, with both builds, before opening SuperFreaker.

Back up first

  • In Arturia MIDI Control Center, save your presets, samples and wavetables to your computer.
  • Keep the official firmware file. SuperFreaker is built for version 5.0.0.2084. Its SHA-256 is c2b405e3c8565b7b73b4dd06522559458190082a8ba633cc5f1bcc43dc64332c, so you can check your copy is the right one.

Flash with the MicroFreak assembled

Flash with the unit fully assembled, as it was sold, keybed attached. Two testers with opened-up units saw MIDI Control Center stop with “Firmware download failed (Timeout)”, on our file and on Arturia’s own, and the update went through once the keybed was back on. If you have taken yours apart, put it back together first.

Go back to the official firmware

  1. Connect the MicroFreak to your computer by USB, with its power supply plugged in.
  2. Open Arturia MIDI Control Center and select the MicroFreak.
  3. Update the firmware with the official file. Your presets saved under SuperFreaker still load on the official firmware; the extra values are ignored.

If the update fails, or it won’t start normally

Start here. This works whatever state the MicroFreak is in.

  1. Switch the MicroFreak off, and check that it is fully assembled.
  2. Hold Shift + Arp + Oct/Mod and switch it on. This asks for the update mode the official updater uses.
  3. In MIDI Control Center, use force upgrade with the official firmware file.
  4. Don’t unplug anything until MIDI Control Center says it has finished.

MIDI Control Center may say it doesn’t recognize the firmware, or close part-way. That is normal for a file that isn’t one of Arturia’s own, so run the force upgrade again.

If MIDI Control Center doesn’t see the MicroFreak at all on Windows, press Ctrl+R to restart Windows MIDI and it finds the unit again. This is a stopgap while we track down the cause.

What the mod never touches

SuperFreaker changes only the main program in the firmware file. The bootloader, the part that lets you re-flash, isn’t in that file, and your unit’s serial number and calibration live in a separate area the patches don’t write to. We still can’t promise every possible failure is recoverable, which is why we rehearsed this guide before release.

SP-404MKII

Rehearsed on Roland’s own file. The way back below uses only Roland’s official update, and we have walked it on our own SP-404MKII. We walked it again with Side-Piece installed before the beta came out.

The Screen Loader

The Screen Loader only adds pictures to a project’s PICTURE folder. To undo it, delete startup_1.bmp, startup_2.bmp and screen_saver_*.bmp from that folder (or put your old ones back), then import the project again. The firmware is never involved.

Back up first

  1. Put an SD card in the SP.
  2. Press SHIFT + pad 13 (UTILITY), choose BACKUP/RESTORE, then BACKUP. Wait until it finishes.
  3. Copy the whole card to your computer, so the backup exists in two places.

Keep your copy of Roland’s official system update 5.52 from Roland’s support site. It is a ZIP with two files inside, SP404MKII_APP0.bin and SP404MKII_APP1.bin. We never host Roland’s files, so we can’t give you one later.

Install Side-Piece

The Side-Piece patcher builds your SP404MKII_APP1.bin from Roland’s update, in your browser.

  1. Use the SD card from your SP (if it’s a new card: format it as FAT32).
  2. Copy your Side-Piece SP404MKII_APP1.bin into the card’s top folder, not into a folder. Your project folders can stay; SP404MKII_APP1.bin should be the only loose file in the top folder, and the name must be exact.
  3. With the SP switched off, put the card in, hold SHIFT and switch it on.
  4. The update screen appears. Press VALUE to start. It takes about 90 seconds. Wait for UPDATE COMPLETE, then switch off.
  5. You can leave the file on the card: the SP only updates when you hold SHIFT at power-on.
  6. Check it worked: SHIFT + pad 13 (UTILITY), SYSTEM, turn CTRL 3 to the VERSION tab.

Side-Piece’s own settings (FX screen, ducker, LFOs) start fresh every time you switch on. Resample what you want to keep.

Go back to Roland’s firmware

Same steps as installing, with Roland’s own file:

  1. Take SP404MKII_APP1.bin out of Roland’s update ZIP.
  2. Copy that file into the card’s top folder in place of the Side-Piece one (the only loose file there).
  3. SP off, card in, hold SHIFT, switch on, press VALUE, wait about 90 seconds for UPDATE COMPLETE, switch off.
  4. The VERSION tab (SHIFT + pad 13, SYSTEM, CTRL 3) reads Version: 5.52 again.

Side-Piece leaves the SP’s start-up and update code exactly as Roland made it (the patcher refuses to build a file that changes them), so this way back stays the same as on a stock unit.

Never do these

  • Never put SP404MKII_APP0.bin on the card. It reflashes the sound chip, and nobody knows a way back if that goes wrong. Roland’s ZIP contains it: copy only SP404MKII_APP1.bin.
  • Update only from the screen you reach by holding SHIFT at power-on, with SP404MKII_APP1.bin as the only loose file in the card’s top folder.
  • Never switch off or pull the power during an update.

If something goes wrong

  • The SP starts but acts strangely: go back to Roland’s firmware (above), then restore your backup with SHIFT + pad 13 (UTILITY), BACKUP/RESTORE, RESTORE.
  • The update screen does not appear: check the card is FAT32, the file is named exactly SP404MKII_APP1.bin, it sits in the top folder (not inside a folder), and you are holding SHIFT before you switch on.

Still stuck

Email [email protected]. Tell us the instrument, which build you flashed, what the screen shows, and which steps you’ve tried. We answer recovery questions first.